Sign In | Join Free | My autochinanet.com
China Xi'an Kacise Optronics Co.,Ltd. logo
Xi'an Kacise Optronics Co.,Ltd.
Kacise, understanding your automation needs.
Verified Supplier

8 Years

Home > Electromagnetic Flow Meter >

Proline Promass E 500 Coriolis flowmeter

Xi'an Kacise Optronics Co.,Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Proline Promass E 500 Coriolis flowmeter

Brand Name : Endress+Hauser

Certification : CE

Place of Origin : Switzerland

Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram

Supply Ability : 1000 Piece/Pieces per Week negotiable

Delivery Time : 5-8 work days

Packaging Details : each unit has individual box and all boxes are packed in standard packages or customers requests available

Model Number : Proline Promass E 500

MOQ : 1PCS

Measuring range : 0 to 180 000 kg/h (0 to 6615 lb/min)

Max. process pressure : PN 100, Class 600, 63K

Medium temperature range : –40 to +150 °C (–40 to +302 °F)

Ambient temperature range : Standard: –40 to +60 °C (–40 to +140 °F)

Transmitter housing material : AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat

Inputs : Status input

Contact Now

"Specs at a glance
Max. measurement error
Mass flow (liquid): ±0.15 % (standard), ±0.10 % (option)
Volume flow (liquid): ±0.15 %
Mass flow (gas): ±0.50 %
Density (liquid): ±0.0005 g/cm³

Measuring range
0 to 180 000 kg/h (0 to 6615 lb/min)

Medium temperature range
–40 to +150 °C (–40 to +302 °F)

Max. process pressure
PN 100, Class 600, 63K

Wetted materials
Measuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L)" "Field of application
The robust Promass E has a long-standing reputation as a reliable solution accurately measuring liquids and gases in a wide range of standard applications in various industries. With its innovative remote transmitter Promass E 500 maximizes installation flexibility and operational safety in demanding environments. Heartbeat Technology enables measurement reliability and extension of recalibration cycles.

Measuring principle operates independently of physical fluid properties such as viscosity or density

Accurate measurement of liquids and gases for a wide range of standard applications


Device properties

Compact dual-tube sensor

Medium temperature up to +150 °C (+302 °F)

Process pressure up to 100 bar (1450 psi)

Remote version with up to 4 I/Os

Backlit display with touch control and WLAN access

Standard cable between sensor and transmitter" "Benefits
Cost-effective – multipurpose device; an alternative to conventional volumetric flowmeters

Fewer process measuring points – multivariable measurement (flow, density, temperature)

Space-saving installation – no in-/outlet run needs

Full access to process and diagnostic information – numerous, freely combinable I/Os and Ethernet

Reduced complexity and variety – freely configurable I/O functionality

Integrated verification – Heartbeat Technology" "Measuring principle
Coriolis

Product headline
Flowmeter with minimized total cost of ownership, as remote version with up to 4 I/Os.
Accurate measurement of liquids and gases for a wide range of standard applications.

Sensor features
Cost‐effective – multi‐purpose device; an alternative to conventional volumetric flowmeters. Fewer process measuring points – multivariable measurement (flow, density, temperature). Space‐saving installation – no in-/outlet run needs.
Compact dual-tube sensor. Medium temperature up to +150 °C (+302 °F). Process pressure up to 100 bar (1450 psi).

Transmitter features
Full access to process and diagnostic information – numerous, freely combinable I/Os and fieldbuses. Reduced complexity and variety – freely configurable I/O functionality. Integrated verification – Heartbeat Technology.
Remote version with up to 4 I/Os. Backlit display with touch control and WLAN access. Standard cable between sensor and transmitter.

Nominal diameter range
DN 8 to 80 (⅜ to 3"")

Wetted materials
Measuring tube: 1.4539 (904L)
Connection: 1.4404 (316/316L)

Measured variables
Mass flow, density, temperature, volume flow, corrected volume flow, reference density, concentration

Max. measurement error
Mass flow (liquid): ±0.15 % (standard), ±0.10 % (option)
Volume flow (liquid): ±0.15 %
Mass flow (gas): ±0.50 %
Density (liquid): ±0.0005 g/cm³

Measuring range
0 to 180 000 kg/h (0 to 6615 lb/min)

Max. process pressure
PN 100, Class 600, 63K

Medium temperature range
–40 to +150 °C (–40 to +302 °F)

Ambient temperature range
Standard: –40 to +60 °C (–40 to +140 °F)
Option: –50 to +60 °C (–58 to +140 °F)

Sensor housing material
1.4301 (304), corrosion resistant
Sensor connection housing (standard): AlSi10Mg, coated
Sensor connection housing (option): 1.4301 (304); 1.4404 (316L)

Transmitter housing material
AlSi10Mg, coated; 1.4409 (CF3M) similar to 316L; Polycarbonat

Degree of protection
Sensor remote version (standard): IP66/67, type 4X enclosure
Sensor remote version (option): IP69. Transmitter remote version: IP66/67, Type 4X enclosure

Display/Operation
4-line backlit display with touch control (operation from outside)
Configuration via local display and operating tools possible

Outputs
4 outputs:
4-20 mA HART (active/passive)
4-20 mA WirelessHART
4-20 mA (active/passive)
Pulse/frequency/switch output (active/passive)
Double pulse output (active/passive)
Relay output

Inputs
Status input
4-20 mA input

Digital communication
HART, PROFIBUS DP, PROFIBUS PA, FOUNDATION Fieldbus, Modbus RS485, MODBUS TCP over Ethernet-APL, PROFINET, PROFINET over Ethernet-APL, Ethernet/IP, OPC-UA

Power supply
DC 24 V
AC 100 to 230 V
AC 100 to 230 V / DC 24 V (non-hazardous area)

Hazardous area approvals
ATEX, IECEx, cCSAus, NEPSI, INMETRO, EAC, KC

Product safety
CE, C-tick, EAC marking

Functional safety
Functional safety according to IEC 61508, applicable in safety-relevant applications in accordance with IEC 61511

Metrological approvals and certificates
Calibration performed on accredited calibration facilities (acc. to ISO/IEC 17025)
Heartbeat Technology complies with the requirements for measurement traceability according to ISO 9001:2015 – Section 7.1.5.2 a (TÜV SÜD attestation)

Marine approvals and certificates
LR approval, DNV approval, ABS approval, BV approval, CCS approval

Pressure approvals and certificates
PED, CRN

Material certificates
3.1 material

Hygienic approvals and certificates
3-A, EHEDG, cGMP"


Product Tags:

Proline Promass E 500 flowmeter

      

Coriolis flowmeter with warranty

      

Electromagnetic flow meter industrial

      
China Proline Promass E 500 Coriolis flowmeter factory

Proline Promass E 500 Coriolis flowmeter Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Xi'an Kacise Optronics Co.,Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)